For quality control managers setting up or auditing X̄–R charts who need the grand mean and average range turned into control limits without re-deriving the A2, D3, D4 and d2 constants for subgroup sizes 2 to 10 from the ISO 7870-2 / AIAG SPC table each time. X-bar and R control limits from the grand mean and the average range, with A2, D3, D4 and d2 looked up for subgroup sizes 2 to 10 (ISO 7870-2 / AIAG SPC constants).
Q: What are the formulas for X-bar and R chart control limits?
A: UCLx = X̿ + A2·R̄, LCLx = X̿ − A2·R̄, UCLr = D4·R̄ and LCLr = D3·R̄, where A2, D3 and D4 come from the ISO 7870-2 / AIAG constants table for the chosen subgroup size.
Q: What is the A2 constant for a subgroup size of 5?
A: A2 = 0.577 for n = 5, so the X-bar limits sit 0.577 × R̄ either side of the grand mean.
Q: Why is the lower control limit for the range chart zero?
A: D3 = 0 for subgroup sizes 2 through 6, so LCLr = D3·R̄ evaluates to exactly 0; D3 only becomes non-zero at n = 7 (0.076).
Q: How is sigma estimated from the average range?
A: sigma = R̄/d2; for n = 4, d2 = 2.059, so an average range of 8.0 units gives an estimated sigma of about 3.89 units.