Queendom Tools

Water Properties Calculator by Temperature

This calculator gives the properties of liquid water at 0.1 MPa from a single temperature: density, isobaric heat capacity, thermal expansivity, isothermal compressibility, speed of sound, viscosity, thermal conductivity and static dielectric constant. It is written for hydraulics, HVAC, laboratory and process engineers who need these values at one state point.

The values come from the correlations of IAPWS SR6-08(2011), Revised Supplementary Release on Properties of Liquid Water at 0.1 MPa, evaluated in double precision with no rounding before display. Enter a temperature in degrees Celsius, kelvin or degrees Fahrenheit between −20 °C and 110 °C; outside the stable liquid range the page marks the result as metastable.

Calculate the properties

Range, limits included: −20 to 110 °C, 253.15 to 383.15 K, −4 to 230 °F. The unit menu only says how to read the typed number.

Liquid water at 0.1 MPa
PropertyValueUnit
Temperature T—K
Density ρ—kg/m³
Isobaric heat capacity cp—J/(kg·K)
Thermal expansivity α—10−6 K−1
Isothermal compressibility κT—GPa−1
Speed of sound w—m/s
Viscosity μ—µPa·s
Thermal conductivity λ—W/(m·K)
Static dielectric constant ε—dimensionless

Phase: enter a temperature and press Calculate.

Uncertainty in the stable range (coverage factor 2): density 0.0001 %, speed of sound 0.005 %, isobaric heat capacity 0.1 %, viscosity 1 %, thermal conductivity 1.5 %; static dielectric constant 0.01 absolute. The digits shown exceed this uncertainty and serve to check Table 8 of the release.

How the values are computed

The temperature T in kelvin is the typed number t when the unit is K, t + 273.15 when it is °C, and (t − 32)/1.8 + 273.15 when it is °F. The release expresses the specific volume v0, its temperature derivative vT, its pressure derivative vp and the isobaric heat capacity cp0 as sums of powers of A = 10/(593 − T) and B = 10/(T − 232), with R = 461.51805 and p0 = 100000 Pa. From these:

How to use the calculator

  1. Type the temperature in the Temperature field.
  2. Choose the unit the number is written in: °C, K or °F. The menu does not change the number; it only tells the calculator how to read it.
  3. Press Calculate, or press Enter in the field.
  4. Read the nine results in the table and check the phase note: below 273.15 K the liquid is metastable subcooled, above 372.76 K it is metastable superheated.
  5. Use the uncertainty note to judge how many of the displayed digits are meaningful for your work.

Frequently asked questions

Which equations does this calculator use?

It uses the correlations of IAPWS SR6-08(2011), Revised Supplementary Release on Properties of Liquid Water at 0.1 MPa. The calculation runs in double precision and nothing is rounded before display.

What temperatures can I enter?

From −20 to 110 °C, from 253.15 to 383.15 K, or from −4 to 230 °F, limits included. Below 273.15 K the result describes metastable subcooled liquid, because the stable phase is ice. Above 372.76 K it describes metastable superheated liquid, because the stable phase is vapor.

How accurate are the results?

In the stable range the uncertainty, with a coverage factor of 2, is 0.0001 % for density, 0.005 % for speed of sound, 0.1 % for isobaric heat capacity, 1 % for viscosity and 1.5 % for thermal conductivity; for the static dielectric constant it is 0.01 absolute. In the subcooled range no uncertainty is given, except about 1 absolute for the dielectric constant. The digits shown exceed the uncertainty and serve to check Table 8 of the release.

Can I change the pressure?

No. All properties refer to liquid water at a fixed pressure of 0.1 MPa, the pressure covered by the release, so temperature is the only input.

Disclaimer

The results are an estimate for documentation only. They are computed from published correlations and are not a substitute for the release itself or for measured data; verify any value before relying on it in a design or safety decision.